Safing Mineral Wool

DESCRIPTION: MinWool1200 Industrial Board Insulation is made of basalt volcanic rock fibers with thermosetting resin binder. Advanced production ensures reliable quality, high fiber density & low shot content for high temperature heat control & fire resisting use.

FEATURES:

  • Thermal insulation gives control over heat loss for lower operating costs
  • Easy to handle, fabricate & cut with a knife; clean handling reduces irritation and minimizes clean-up & expense
  • Does not support fungi/mold

PERFORMANCE: Tested in accordance with ASTM E84 (UL 723), CAN/ULC-S102-M (flame spread rating of 5 and smoke developed rating of 0; faced insulation has flame spread rating of 25 and smoke developed rating of 5); noncombustible in accordance with ASTM E136 and CAN4-S114-M

Read More

Metacaulk Wrap Strip

DESCRIPTION: Flexible, precured dry intumescent strips used mainly for plastic & insulated pipe applications, wrapped simply around penetrating item(s) to completely fill annular space. In addition, for use with a universal collar for engineered plastic pipes 8 in. diameter and greater.

FEATURES:

  • Intumescent expands at the exposure of heat, forming a refractory char that tightly seals preventing the spread of flame, smoke and toxic fumes
  • Easy to install; no cure time
  • Excellent freeze-thaw
  • Highly versatile, flexible; economical
  • Long length means less waste
  • Systems up to 14″ PVC

PERFORMANCE: Tested in accordance with ASTM E814 (UL 1479); VOC compliant (CDPH Standard Method v1.2); complies to Required Environmental Exposure Testing of Accelerated Aging and High Humidity as per UL 1479 Fire Test of Through-Penetration Firestops; tested by a third party independent laboratory to the ASTM G21 standard with Fungal Growth Rating results of zero

Read More

Metacaulk RS 136 Fire Block / Smoke Seal Caulk

DESCRIPTION: Incombustible fire-block, smoke-seal, acoustic-block and draft-stop caulk that beds and seals small voids, splices and gaps. Not for use in continuous vibration or wet environments.

FEATURES:

  • Inorganic material with no volatile solvents (particularly useful when installing in confined spaces or occupied areas); does not have asbestos fillers
  • An easy installation sealant with water cleanup capabilities; no mixing or special skills necessary & no required additives; applied with a conventional caulking gun
  • Excellent freeze-thaw
  • 2-year shelf life

PERFORMANCE: UL Classified system; tested in accordance with ASTM E136

Read More

Metacaulk Putty Sticks

DESCRIPTION: Moldable, non-curing, single-component, intumescent pliant in stick form for through-penetration systems.

FEATURES:

  • Intumescent expands at the exposure of heat, forming a refractory char that tightly seals preventing the spread of flame, smoke and toxic fumes
  • For interior use with various penetrations (cabling, EMT pipe, conduit, etc.); no volatile solvents (particularly useful when installing in confined spaces or occupied areas); does not have asbestos fillers
  • Easy to install; applied by hand; no curing time; adheres to all common building surfaces
  • Helps provide a barrier or buffer for energized bus ducts or conduits as well as provide a barrier from vibration and movement; no additional putty material needed to plug end of each electrical metallic tube or conduit as its connection to the box
  • Required by Building Codes in rated partitions where horizontal separation of opposite facing electrical boxes is under 24 inches

PERFORMANCE: UL Classified system up to 3 hrs; tested in accordance with ASTM E814 (UL 1479), ASTM E119 (UL 263); VOC compliant (CDPH Standard Method v1.2); tested by a third party independent laboratory to the ASTM G21 standard with Fungal Growth Rating results of zero; STC Rating 60

Read More

Metacaulk Putty Pads

DESCRIPTION: Moldable, non-curing, single-component, intumescent pliant in pad form for through-penetration systems.

FEATURES:

  • Intumescent expands at the exposure of heat, forming a refractory char that tightly seals preventing the spread of flame, smoke and toxic fumes
  • For interior use with various penetrations (cabling, EMT pipe, conduit, etc.); no volatile solvents (particularly useful when installing in confined spaces or occupied areas); does not have asbestos fillers
  • Easy to install; applied by hand; no curing time; adheres to all common building surfaces
  • Helps provide a barrier or buffer for energized bus ducts or conduits as well as provide a barrier from vibration and movement; no additional putty material needed to plug end of each electrical metallic tube or conduit as its connection to the box
  • Required by Building Codes in rated partitions where horizontal separation of opposite facing electrical boxes is under 24 inches

PERFORMANCE: UL Classified system up to 3 hrs; tested in accordance with ASTM E814 (UL 1479) and ASTM E119 (UL 263); STC Rating 60; only 1/8″ thickness needed for 1-2 hr fire rating; tested by a third party independent laboratory to the ASTM G21 standard with Fungal Growth Rating results of zero

Read More

Metacaulk Mortar

DESCRIPTION: Rapid-hardening compound of gypsum and cement for large opening through-penetrations in floors and walls (ideal for cable trays, power cables, fiber optic telephone cables, etc. [not aluminum]).

FEATURES:

  • Best combination of workability, strength & fire resistance; safe and simple to use; high yield per pound
  • Workable in approximately 45 minutes with non-sag adjustable consistency (pourable or trowelable); no special tools needed to mix or install
  • Ideal for large openings containing multiple penetrants
  • Sets without shrinking; forms rigid, gas tight, fire-resistant seal that can easily be cut/drilled/resealed if future penetrants are needed
  • Protected in wet & dry stages against mold growth with a combination of biocides

PERFORMANCE: UL Classified system up to 4 hrs; tested in accordance with ASTM E814 (UL 1479)

Read More

Metacaulk Joint Strip

DESCRIPTION: Flexible, precured dry intumescent strips used for concrete & masonry floor & wall joints up to 2″ (51 mm) wide, duct insulation and up to 4″ PVC/CPVC & membrane penetrations.

FEATURES:

  • Intumescent expands at the exposure of heat, forming a refractory char that tightly seals preventing the spread of flame, smoke and toxic fumes
  • Easy to install; single-sided application
  • Highly versatile, flexible; economical
  • May be covered with any color standard architectural caulk; no firestop caulk required

PERFORMANCE: UL Classified system up to 3 hrs; tested in accordance with ASTM E814 (UL 1479) & ASTM E1966 (UL 2079); VOC compliant (CDPH Standard Method v1.2); complies to Required Environmental Exposure Testing of Accelerated Aging and High Humidity as per UL 1479 Fire Test of Through-Penetration Firestops

Read More

Metacaulk Intumescent Sleeves

DESCRIPTION: Flexible design of durable galvanized steel outer shell lined with precured dry intumescent that easily conforms to contours of pipes for through-penetrations and angled penetrations, ideal for retrofit and flammable pipes penetrating an uneven concrete fluted deck assembly.

FEATURES:

  • Intumescent expands at the exposure of heat, forming a refractory char that tightly seals preventing the spread of flame, smoke and toxic fumes
  • Easy installation without modifications, steel bolts or fasteners; fasten with fiberglass tape, pop rivets or hose clamps around pipe
  • Economical and saves on labor cost; no measurement of material required
  • No need to firestop both wall penetration sides; can be installed from top or underside for floor applications; eliminates need for collars/wrap strips
  • Can be retrofitted, easily removed and replaced material
  • Ideal for large PVC or engineer plastic pipes going through concrete fluted decks
  • Ideal for applications when pipes are installed on at an angle
  • Ideal for installing around a coupling located in floor and wall openings

PERFORMANCE: UL Classified system up to 3 hrs; tested in accordance with ASTM E814 (UL 1479) and CAN/ULC-S115; tested for PVC, CPVC, ABS and PVC/ABS Foam Core, FRPP, PP; VOC compliant (CDPH Standard Method v1.2); complies to Required Environmental Exposure Testing of Accelerated Aging and High Humidity as per UL 1479 Fire Test of Through-Penetration Firestops

Read More

Metacaulk Intumescent Collars

DESCRIPTION: Prefabricated device with precured dry intumescent designed for the circumference of open and closed through-penetrations diameters from 1 & 1/2″ up to 6″ (38 – 152 mm), with securing interlocking tab mechanism for easy installation.

FEATURES:

  • Intumescent expands at the exposure of heat, forming a refractory char that tightly seals preventing the spread of flame, smoke and toxic fumes
  • Economical, easy to install, saves on labor; design greatly cuts time and expense comparatively
  • Fits in limited access areas; no measurement of material required
  • FBC System compatible

PERFORMANCE: UL Classified system up to 3 hrs; tested in accordance with ASTM E814 (UL 1479) and CAN/ULC-S115; tested for PVC, CPVC, ABS and PVC/ABS Foam Core, FRPP, PP, and Aquatherm; tested by a third party independent laboratory to the ASTM G21 standard with Fungal Growth Rating results of zero; complies to Required Environmental Exposure Testing of Accelerated Aging and High Humidity as per UL 1479 Fire Test of Through-Penetration Firestops

Read More

Metacaulk Firestop Pillows

DESCRIPTION: Ready-to-install package of layered precured dry intumescent, made for use in large openings with cables, cable trays, blank openings or multiple penetrating items.

FEATURES:

  • Intumescent expands at the exposure of heat, forming a refractory char that tightly seals preventing the spread of flame, smoke and toxic fumes
  • Easy to install with no tools and no cure time required; no wire mesh required in certain installations (some UL designs using multiple pillows require sealant or putty to fill in the gaps)
  • Reusable & can be removed/reinstalled if needed
  • Cost effective and versatile
  • Two sizes available

PERFORMANCE: UL Classified system up to 3 hrs; tested in accordance with ASTM E814 (UL 1479) and CAN/ULC-S115; VOC compliant (CDPH Standard Method v1.2); complies to Required Environmental Exposure Testing of Accelerated Aging and High Humidity as per UL 1479 Fire Test of Through-Penetration Firestops