RRg – Silicone

[table id=2 /]
Michael Rizza™ Premium Silicone System
RELATED: RWg
JOINT SIZE: 2-12″+ (Custom larger sizes may be available; contact Balco directly)
MOVEMENT: ±50% Expansion/Contraction; ±50% Vertical Shear
FEATURES:
Premium silicone seal roof bellow; No exposed fasteners; Surface mount installation only; Multiple silicone color options available (see Color Chart for details); Comes standard with water barrier; Drain assemblies available; Aluminum Ships in 10′ lengths; silicone ships in up to 100′ lengths
PERFORMANCE: Seismic, thermal and wind movement per ASTM E1399 standard; Contributes to LEED® credits

Read More

BRB – Traditional

[table id=5 /]
RELATED: BRBA, BRBC, BRBG, BRBS, BRBWC
JOINT SIZE: 2-24″ (Custom larger sizes may be available; contact Balco directly)
MOVEMENT: ±50% to ±100% Expansion/Contraction; ±50% to ±100% Vertical Shear; Lateral Shear Varies
FEATURES:
Factory-fabricated roof bellow transitions available; Surface mount installation only; Flexible membrane options available (EPDM & PVC); Closed cell support foam; Curb flange, straight flange and wide curb flange available; multiple flange metal options available*; Ships in 10′ lengths
PERFORMANCE: Seismic, thermal and wind movement per ASTM E1399 standard; Contributes to LEED® credits

*See Color Chart for details

Read More

BBSW – Pre-compressed Secondary Seal

JOINT SIZE: 0.5-8″
MOVEMENT: ±50% Expansion/Contraction
FEATURES: Easy to Install; Installs without mechanical fasteners; UV stable, chemically resistant, watertight, mildew resistant, dust-proof, airtight, sound resistant, insulated; Ships in 5′ lengths
PERFORMANCE: Meets 21 psi min. tensile strength per ASTM 3574; Self-extinguishing per UL 94VO; flame spread 0 per ASTM E84; Sound transmission loss rating as high as 50 STC, 46 OITC per ASTM E90; Air leakage (L Rating) minimum of <0.01 cfm/ft2 per ASTM E 283; 12 psf water resistance per ASTM E331; Seismic, thermal and wind movement per ASTM E1399 standard; Contributes to LEED® credits

Hospitals and Healthcare Buildings Flyer

Read More

BCSWE – Non Pre-compressed Primary Seal

JOINT SIZE: 0.5-10″
MOVEMENT: ±25% Expansion/Contraction
FEATURES: Easy to Install; Installs without mechanical fasteners; UV stable, chemically resistant, watertight, mildew resistant, dust-proof, airtight, sound resistant, insulated; Multiple silicone color options available (see Color Chart for details); Ships in 5′ lengths
PERFORMANCE: Sound transmission loss rating as high as 36 STC, 35 OITC per ASTM E90; No-cracking weather resistance per ASTM D1499; Water absorption <.02lbs/ft2 per ASTM D1499; Seismic, thermal and wind movement per ASTM E1399 standard; Contributes to LEED® credits

Read More

BCSW – Pre-compressed Primary Seal

[table id=8 /]
View fire-rated foam
JOINT SIZE: 0.5-12″
MOVEMENT: ±50% Expansion/Contraction
FEATURES: Easy to Install; Installs without mechanical fasteners; UV stable, chemically resistant, watertight, mildew resistant, dust-proof, airtight, sound resistant, insulated; Multiple silicone color options available (see Color Chart for details); Ships in 5′ lengths
PERFORMANCE: Meets 21 psi min. tensile strength per ASTM 3574; Flame spread 0 (self-extinguishing) per ASTM E84; Sound transmission loss rating as high as 50 STC, 46 OITC per ASTM E90; Air leakage (L Rating) minimum of <0.01 cfm/ft2 per ASTM E 283; Passes water penetration test per ASTM E 547 and ASTM E 331; Seismic, thermal and wind movement per ASTM E1399 standard; Contributes to LEED® credits

Retrofit Flyer

Read More

Continuing Education Program

We offer the following courses and learning credits: Balco is an approved provider of American Institute of Architects (AIA) Certified Continuing Education courses. Our provider number is #K437. Review the
Read More

HDHP – Heavy Duty Hinge Plate

[table id=4 /]
RELATED: HDHPL
JOINT SIZE: 6-24″ (Custom larger sizes may be available; contact Balco directly)
MOVEMENT: ±50% to ±100% Expansion/Contraction; ±50% to ±100% Lateral Shear; Vertical Shear varies; Contact factory for details
FEATURES:
Easy to install; Easy to clean; Designed for heavy loading; Specifically designed to accommodate horizontal & vertical shear; Sound-dampening; Surface mount installation only; Ideal for retrofit; Comes standard with water barrier; Drain assemblies available; Ships in 10′ lengths
PERFORMANCE: Seismic, thermal and wind movement per ASTM E1399 standard; Meets ADA guidelines for slip resistance; Contributes to LEED® credits
LOAD: Pedestrian, Slow Vehicular (See Load Data Sheet for details)

Read More

MPSW3H (MetaFlex® Pro Shear Wall) – 3 Hour

RELATED: MPSWC3H
JOINT SIZE: 4-12″ (max 8-18″ open)
MOVEMENT: ±50% to ±100% Expansion/Contraction, Lateral and Vertical Shear Vary (by Joint Size)
FEATURES: Fire-resistant barrier for vertical expansion joints; Doubles as smoke barrier; Fire protection from both directions; Convenient single-package installation; Intuitive lap splicing; Ships in 10′ lengths; Can be integrated with Balco Expansion Joint Systems
PERFORMANCE: Fire resistance rating of 3 hours tested in accordance with ASTM E1966 and UL 2079; Air leakage (L rating) <5 SCFM/LF per UL 2079, meets IBC 715.3 and IBC 715.6; Intumescent BlazeSeal™ seal beneath flanges is tested in accordance with UL 1479; Seismic, Thermal and Wind movement tested per standard ASTM E 1399; Contributes to LEED® credits

Read More

TRXM (Eclipse™ System) – Mid-range Surface Mount Plate

[table id=4 /]
RELATED: TRXME
JOINT SIZE: 6-24″ (See the TRX for larger sizes)
MOVEMENT: ±50% to ±100% Expansion/Contraction; ±50% to ±100% Lateral Shear; Vertical Shear Varies
FEATURES:
Durable aluminum cover; Withstands loads from snow, wind and seismic activity; Easy to assemble and install; Full, multi-directional (three-axis) movement; Surface mount installation only; Comes standard with water barrier; Drain assemblies available; Kynar or anodized options available (to match surrounding construction; see Color Chart for details); Ships in max 10′ lengths (cut at factory)
PERFORMANCE: Seismic, thermal and wind movement per ASTM E1399 standard; Snow, wind and seismic loading per ASCE 7; Contributes to LEED® credits

 

Read More

Metacaulk Pass Thru Pro (PATP)

DESCRIPTION: Firestop device that protects through-penetrations for up to 4 hours while providing flexibility to add, re-add or remove penetrants at any time.

FEATURES:

  • Reduces labor time with quick installation and flexibility to modify penetrants as often as needed
  • Intumescent expands at the exposure of heat, forming a refractory char that tightly seals preventing the spread of flame, smoke and toxic fumes
  • Will not mechanically pinch cables
  • Available in 2” (50mm) Round, 4” (102mm) Round, and 4” (102mm) Square (as Single, Double, Tri-Plex, Six-Plex)
  • Up to 4-hour fire rating
  • Excellent “L” rating
  • Zero maintenance

PERFORMANCE: UL Classified system up to 4 hrs; tested in accordance with UL 1479

Metacaulk Pass Thru Pro One-sheet