JOINT SIZE: 1-4″ (max 6″ open)*
MOVEMENT: ±50% to ±100% Expansion/Contraction
FEATURES: Versatile, fire-resistant barrier for horizontal expansion joints; Installs without mechanical fasteners or fire caulking; Minimal depth of 2 1/2″ required for installation; Ships in 7′, tongue and groove lengths for easy splicing and transitioning; Ideal for use with elastomeric seals
PERFORMANCE: Fire resistance rating of 1-4 hours tested in accordance with ASTM E1966 and UL 2079; Seismic, Thermal and Wind movement tested per standard ASTM E 1399; Contributes to LEED® credits
(*Joint size availability varies slightly between products.)
CAD
(MBF2H) |
MBF2H0125 MBF2H0238 MBF2H0350 MBF2H0450S MBF2H0600 |
BIM
(MBF2H) |
View MBF |
Technical Data
(MBF2H) |
MetaBlock_TechData |
Installation Instructions
(MBF2H) |
MetaBlock-Floor-2H-600_Install MetaBlock-Floor-2H-UpTo450_Install |
Install Demo Video |
Additional Info
Short Spec | 3-Part Spec | LEED | UL/Intertek |
MetaBlock_ShortSpec | EJC-07-95-13_3PartSpec | Balco LEED Brochure | FF-D-1141 FF-D-1137 FF-S-0035 FF-D-1140 FF-D-1071 FF-D-1138 FF-D-0059 FF-D-1139 FF-D-1137 ULC FF-D-1138 ULC FF-D-1139 ULC FF-D-1140 ULC |
Related products
-
MetaBlock®
MBF4H – 4 Hour
0 out of 5(0)JOINT SIZE: 1-4″ (max 6″ open)*
MOVEMENT: ±50% to ±100% Expansion/Contraction
FEATURES: Versatile, fire-resistant barrier for horizontal expansion joints; Installs without mechanical fasteners or fire caulking; Minimal depth of 2 1/2″ required for installation; Ships in 7′, tongue and groove lengths for easy splicing and transitioning; Ideal for use with elastomeric seals
PERFORMANCE: Fire resistance rating of 1-4 hours tested in accordance with ASTM E1966 and UL 2079; Seismic, Thermal and Wind movement tested per standard ASTM E 1399; Contributes to LEED® credits(*Joint size availability varies slightly between products.)
SKU: n/a -
MetaBlock®
MBF3H – 3 Hour
0 out of 5(0)JOINT SIZE: 1-4″ (max 6″ open)*
MOVEMENT: ±50% to ±100% Expansion/Contraction
FEATURES: Versatile, fire-resistant barrier for horizontal expansion joints; Installs without mechanical fasteners or fire caulking; Minimal depth of 2 1/2″ required for installation; Ships in 7′, tongue and groove lengths for easy splicing and transitioning; Ideal for use with elastomeric seals
PERFORMANCE: Fire resistance rating of 1-4 hours tested in accordance with ASTM E1966 and UL 2079; Seismic, Thermal and Wind movement tested per standard ASTM E 1399; Contributes to LEED® credits(*Joint size availability varies slightly between products.)
SKU: n/a